Volkswagen Touran Service Manual: Battery Charger -VAS5095A- Maintenance Charging

  WARNING
Risk of injury. Follow all Warnings and Safety Precautions. Refer to → Chapter "Warnings and Safety Precautions".
  WARNING
Batteries that have a light yellow visual indicator do not have to be tested or charged. Jump starting must not be used!
There is a risk of explosion during testing, charging or jump starting.
These batteries must be replaced.
During maintenance charging, the Battery Charger -VAS5095A- provides safe charging and preserves the charge of the battery.
  Proceed as when charging the battery. Refer to → Chapter "Battery, Charging with Battery Charger -VAS5095A-".
  Note
If the battery is discharged by an electrical consumer during maintenance charging, the Battery Charger -VAS5095A- automatically supplies the appropriate charge.
Maintenance charging can be performed without time restrictions.
The battery can be used constantly.
   
Support Mode with Battery Charger -VAS5095A-
General Information The support mode provides the vehicle electrical system with voltage when the battery is removed or disconnected. ...

Battery Charger -VAS5900- Device Description
  WARNING Risk of injury. Follow all Warnings and Safety Precautions. Refer to → Chapter "Warnings and Sa ...

Other materials:

Volkswagen Touran Service Manual. Flat Connector Systems
  Note If necessary, housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing the contacts. Refer to → Chapter "Secondary Lock".     ...

Volkswagen Touran Service Manual. Refrigerant Circuit
A/C System Repair Information An A/C system made for refrigerant R12 must not be filled with refrigerant R134a without making modifications to the refrigerant circuit. Refer to → Chapter "Refrigerant Circuit, Converting R12 to R134a and Servi ...