Volkswagen Touran Service Manual: Battery, Testing using Midtronics Battery Tester -MCR340VKT-

WARNING
| Read and follow the Safety Precautions when working
with batteries. Refer to
→ Chapter "Warnings and Safety Precautions". |
| Batteries that have a light yellow visual indicator
do not have to be tested or charged. Jump starting must
not be used! |
| There is a risk of explosion during testing,
charging or jump starting. |
| These batteries must be replaced. |
|
| |
Read the General Description. Refer to
→ Chapter "General Information". |
| |
Visually check the battery. Refer to
→ Chapter "Visual Inspection". |
| |
Open the hood or open the cover if the battery is installed
somewhere else. |
| |
Determine if it is a "Standard" battery or an "AGM" battery. |
| |
Remove the covers on the battery positive and negative
terminals. |
| |
Use a fender protector or some type of cover before using
any equipment inside the engine compartment or inside the
passenger compartment. |
 Note
| The battery temperature must be at least 10 C (50 F). |
| Refer to the Battery Tester Charger Kit -VASRX3000-
Operating Instructions for more information. |

WARNING
| Batteries that have a light yellow visual indicator
do not have to be tested or charged. Jump starting must
not be used! |
| There is a risk of explosion during testing,
charging or jump starting. |
| These batteries must be replaced. |
|
| |
Turn off the ignition and all electrical consumers. |
| |
Check the visual indicator. Refer to
→ Chapter "Battery with Visual Indicator, Checking". |
| |
Clamp the red clamp "+" of the tester to the positive
terminal. |
| |
Clamp the black clamp "-" on the tester to the negative
terminal. |
 Note
| Make sure the test clamps make good contact! |
| |
Select "inside the vehicle" or "outside of the vehicle". |
 Note
| If the test results are needed to process a warranty claim,
use the print function on the Midtronics Battery Tester
-MCR340VKT-. |
| |
Determine if it is a "Standard" battery or an "AGM" battery. |
| |
Enter the battery DIN value taken from the battery label. If
the label does not state a DIN value, then enter the SAE value. |
| |
Enter the DIN value into the tester and then perform the
battery test. Refer to MCR340V Operating Instructions. |
| |
If using an SAE value, go into the menu under "other" and
change "DIN" to "SAE". Refer to MCR340VKT Operating
Instructions. |
 Note
| Always use the DIN value on the battery label. Otherwise the
test result will be incorrect. |
|
Evaluating Test Results
| Battery Test Result |
Measure |
| Battery good |
None |
| Good - charge |
Charge battery. Refer to
→ Chapter "Battery Tester Charger Kit -GRX3000VAS-". |
| Use in charge |
Charge battery. Refer to
→ Chapter "Battery Tester Charger Kit -GRX3000VAS-". |
| Replace the battery. |
Replace the battery. Refer to
→ Electrical Equipment; Rep. Gr.27 |
| Battery cell defective |
Replace the battery. Refer to
→ Electrical Equipment; Rep. Gr.27 |
Midtronics Battery Tester -MCR340VKT-, Troubleshooting
| Sometimes the display shows the malfunction or the messages
based on the condition. |
| The following is a list of the most frequent displayed
messages together with suggested solutions. |
 Note
| Refer to the MCR340V Operating Instructions for messages not
listed here. |
|
|
|
| Display Message |
Measure |
| No display |
| |
Make sure the battery tester terminals are attached securely
to the battery terminals. |
| |
Make sure the battery pole is tightened to the tightening
specification and is not corroded. |
| |
Charge battery. Refer to
→ Chapter "Battery Tester Charger Kit -GRX3000VAS-". |
|
| System noises |
| |
Switch off all electrical consumers. |
| |
Wait until all electrical equipment, which are monitored by
the vehicle electrical system control module, are switched off.
|
| |
Disconnect any doubtful or standard production electrical
equipment from the vehicle electrical system. |
|
| Wait a few minutes and then perform the test again. Refer to
→ Chapter "Battery, Testing using Midtronics Battery Tester
-MCR340VKT-". |
 Note
| If the test was performed at the battery jump start terminal
and the message still does not go away, then perform the test
directly on the battery. |
|
|
|
WARNING
Risk of injury.
Read and follow the Safety Precautions when working
with batterie ...
WARNING
Batteries that have a light yellow visual indicator
do not have to be tested or charged. Jump starting must
...
Other materials:
Volkswagen Touran Owners Manual. Introduction
This chapter contains information on the following subjects:
→ Ignition lock
→ Starting the engine
→ Switching off the engine
→ Electronic immobilizer
→ Engine pre-heating
Immobilizer display
If the vehicle key is not valid or the ...
Volkswagen Touran Owners Manual. Operation
First read and observe the introductory information
and safety warnings The auxiliary heater exhaust system, located under the
vehicle, must not be blocked by snow, mud or other items. The exhaust fumes must
not be obstructed in any way. The emissions generated by the auxiliary heater are
...
© 2016-2026 Copyright www.vwtouran.net | 0.0068