VW Touran manuals

Volkswagen Touran Service Manual: Safety Precautions

General Safety Precautions

As per VBG 20, German industrial liability insurance association.
Follow the instructions for the workplace. They should be displayed in the workplace.
   

Product Characteristics

Refrigerants used in motor vehicle air conditioning systems belong to the new generation of refrigerants based on chlorine-free, partially fluorinated hydrocarbons (H-FKW, R134a).
With regard to their physical properties, these are refrigerants which have been liquefied under pressure. They are subject to the regulations governing pressure vessels and use is only to be made of approved and appropriately marked containers.
Compliance with specific conditions is required to ensure safe and proper use.
   

Handling Refrigerant

  WARNING
There is a danger of ice-up.
The refrigerant can then escape as a fluid or vapor.
Do not open containers which store refrigerant.
If refrigerant vessels are opened, the contents may escape in liquid or vapor form. This process is intensified the higher the pressure in the vessel.
The pressure level is governed by two factors:
The type of refrigerant in the vessel. "The lower the boiling point, the higher the pressure."
The temperature level. "The higher the temperature, the higher the pressure."
   

Protective Eyewear

Put on protective goggles. They prevent refrigerant getting into the eyes, as this could cause severe injury from exposure to cold.

Protective Gloves and Clothing

Greases and oils dissolve readily in refrigerants. They would therefore destroy the protective layer of grease if allowed to come into contact with the skin. Degreased skin is however sensitive to the cold and germs.
   

Fluid Refrigerant and Skin Precaution

The refrigerant draws heat for evaporation from the surrounding area. Even if this is the skin. This may cause extremely low temperatures. Local frost bite may result (boiling point of R134a: -26.5 C (-15.7 F) at ambient pressure).
   

Do Not Breath In Refrigerant Vapor

  Note
If highly concentrated refrigerant vapor escapes, it mixes with the surrounding air and displaces the oxygen necessary for breathing.
   

Smoking Hazard

A burning cigarette can cause refrigerant to decompose. The resultant substances are toxic and must not be inhaled.
   

Welding and Soldering on Refrigeration Systems

Before performing welding or soldering work on vehicles near the air conditioning system components, extract the refrigerant and remove the residue by flushing with compressed air and nitrogen.
The products of refrigerant decomposition due to the effect of heat are not only toxic, but may also have a highly corrosive effect on pipes and system components. They mainly take the form of hydrogen fluoride.
   

Pungent Odor

A pungent odor indicates that the products of decomposition mentioned above have already formed. Avoid inhaling these substances under all circumstances, as otherwise the respiratory system, lungs and other organs could be damaged.

First Aid

Following contact with eyes or mucous membranes, immediately rinse with copious amounts of running water and consult an eye specialist.
Following contact with the skin, immediately remove affected clothing and rinse skin with copious amounts of water.
Following inhalation of highly concentrated refrigerant vapors, immediately take the affected person into the open air. Call a doctor. Administer oxygen in the event of breathing difficulties. If the affected person has difficulty breathing or cannot breathe, tip head back and perform mouth to mouth respiration.
   

Handling Pressure Vessels

Secure vessels to prevent them falling over!
Secure upright cylinders to stop them falling over and cylinders lying flat to stop them rolling away.
Do not throw vessels!
If dropped, the vessels could be so severely deformed that they rupture. The refrigerant evaporates immediately, liberating considerable force. Flying fragments of cylinders can cause severe injuries.
Valves may break off if cylinders are not properly transported. To protect the valves, cylinders are only to be transported with protective cap screwed on.
Never store in the vicinity of radiators.
High temperatures may occur next to radiators. High temperatures are also accompanied by high pressures and the maximum permissible vessel pressure may be exceeded.
   

Not Warming Above 50 C (122 F)

To avoid possible risk, pressure vessel regulations specify that vessels are not to be heated to in excess of 50 C (122 F).
   

Heating Warning

Do not heat with a naked flame under any circumstances. Localized overheating can cause structural changes in the vessel material, which then reduce its ability to withstand pressure. There is also a danger of refrigerant decomposition due to localized overheating.
   

Empty Containers

Empty refrigerant vessels must always be sealed to prevent the ingress of moisture. Moisture causes steel vessels to corrode. This weakens the vessel walls. In addition, rust particles entering into refrigeration systems from vessels will cause malfunctioning.
   

Extraction and Charging System Safety Regulations

Make sure the shut-off valves are closed before connecting the charging system to the air conditioning system.
Make sure the process is finished before disconnecting the charging system from the A/C system. This prevents any refrigerant from escaping into the atmosphere.
Once the purified refrigerant from the charging system has been transferred to an external compressed-gas cylinder, close the hand shut-off valves at the cylinder and charging system.
Do not expose charging system to moisture or use it in a wet environment.
Disconnect from power supply before performing service work on the charging system.
Never use an extension cable on account of the fire hazard. If the use of an extension cable is unavoidable, the minimum cross-section should be 2.5 mm2.
In case of fire, remove the external cylinder.
Entrained oil from the air conditioning system drawn by the suction unit into the measurement vessel supplied is subsequently to be transferred to a sealed container as it contains a small quantity of refrigerant. It must not be released into the environment.
Following shutdown, A/C service station is to be secured to stop it rolling away.
   
A/C System Operation
The temperature in the passenger compartment depends on the amount of heat radiated through the windows and conducted by the metal parts of the body. In hot weather i ...

A/C System and Refrigerant R134a Safety Precautions
A/C Service Station -VAS6007A- (and further or current A/C Service Station) Refer to the Workshop Equipment Catalog. ...

Other materials:

Volkswagen Touran Owners Manual. Checklist
To ensure your own safety and the safety of your passengers, observe the following points in the order given  : Find a flat and firm surface suitable for lifting the vehicle. Stop the engine, select a gear of the manual gearbox or move the selector lever of the automatic gearbox ...

Volkswagen Touran Service Manual. Two-Part HS Vario Filler
Definition: Two-Part HS Vario Filler -LGF 786 004 A4-, gray Edition 04/2013 Product Description The two-part vario filler is a high-quality, variable VOC compliant, acrylic-b ...

© 2016-2024 Copyright www.vwtouran.net | 0.0253