VW Touran manuals

Volkswagen Touran Service Manual: Refrigerant Circuit, Flushing

  Note
For vehicles in which no adapters fit on to the refrigerant pipes, for example, a blower pistol with rubber mouthpiece is to be used to blow through individual components. Special care must be taken not to damage the connections (crushing or scratching).
Evaporator is to be flushed via the connection for low-pressure pipe (large diameter) after removing expansion valve or removing restrictor.
Always flush components in direction opposite of refrigerant flow direction.
Check expansion valve and replace if dirty or corroded.
If there are dark, sticky deposits in the components that cannot be removed with compressed air, replace these components.
Thin, light grey deposits on the insides of refrigerant pipes do not impair the function of the components.
After flushing, always replace receiver/dryer or reservoir and restrictor. Replace dryer cartridge or dryer on condensers with attached dryer.
   
General Information
In order to be able to force moisture and other contaminants out of refrigerant circuit, compressed air and nitrogen (to force moisture out of refrigerant circuit) ar ...

Refrigerant Circuit, Flushing (Cleaning) with Refrigerant R134a
...

Other materials:

Volkswagen Touran Service Manual. Customer Service Paint Paint Structure
Galvanized Sheet Metal on Both Sides Previous attempts to match flanges have led to the use of only galvanized sheet metal on both sides. Only here do the cathodic protection and the zinc coating barrier effect work optimally together. T ...

Volkswagen Touran Service Manual. Two-Part Wash Primer
Definition: Two-Part Wash Primer -LHV 043 000 A2- Edition 10/2010 Product Description The two-part wash primer is a zinc chromate-free, phenol-free and acid-free two-componen ...

© 2016-2024 Copyright www.vwtouran.net | 0.0173